| Photo Credit: PublicDomainPictures |
Hospital water systems are a significant source of Legionella, resulting in the potentially fatal Legionnaires’ disease – but Flinders University researchers have proven simple maintenance that involves running hot water regularly and flushing the pipes has a huge effect in reducing the risk of the disease.
One of the biggest challenges for Legionella management within large hospital systems is that under unfavorable conditions, Legionella transforms itself into a state (called viable but non culturable – VBNC) that cannot be detected using standard methods.
To understand the extent of the problem, Flinders University researchers conducted the first comprehensive study that quantified all Legionella, including those in the VBNC state, and free-living amoebae from a hospital water system under dynamic flow and temperature conditions.
“We took a different approach because we didn’t know how often the standard method was returning false negative results for Legionella and it’s really hard to determine the optimal management approach if you can’t trust your testing method,” says Flinders University’s Associate Professor Harriet Whiley.







.jpg)

.jpg)